Unreleased (pre-release)
Pembris Electrical hasn’t had its first release yet. Everything below is in the current pre-release builds and may still change before release. What’s new in Revit lists the changes in the version you have installed.
Routing
- Route A→B suggests a route between devices or conduit ends for review, clear of every element set to Avoid, with permitted penetrations listed.
- Up to three route suggestions to compare by length, elbows and height. Turn this off with Multiple route suggestions in My settings › Routing.
- In the review, More › Change sets the openings, direction, height, conduit type and size for that route only. Closing a Change returns to the same suggestion, and Back to previous restores the route from before.
- Two to four conduits side by side between two boxes with free openings, at a gap you set in More › Change layout.
- Add and route next (Ctrl+Enter) routes several pairs in a row from the last end; Remove last route undoes one.
- A refused route offers its fix as a button, such as Choose openings, Change layout, Smaller conduit, Search further or Reduce clearance, and plans again in the same command.
- Routes use the real size of your project’s elbows and keep the straight run each elbow needs. Each run keeps within your bend limit between pull points, 360° unless you change it.
- New settings start on Default height Above the ceiling, so runs keep to the ceiling void, or under the slab without a ceiling.
- Sockets, switches and lights without conduit connectors can be routed to; the review marks that end Not joined. A device inside another element, such as a socket in its box, gets a short straight way out.
- A route that continues an existing run keeps its conduit type, size and Service Type. A route leaves the building through an exterior wall only when it must, and the review names that run.
- Optional plan wires connect devices or selected conduit ends, with three styles and a curve width.
- Connect devices connects picked devices, a circuit and its panel, or a box of chosen types as a chain or a tree, in one undo step.
- Drop to Tray gives each device its own drop to a tray, with remembered style, reach and clamps. Optional project targets estimate how full the receiving tray gets.
- Project zones: draw spaces that routes prefer, stay inside or keep out of, and choose a route’s zones in its review with More › Change zones.
- An unloaded linked model stops routing until you reload it or choose Ignore this link. A small window shows progress and lets you cancel planning, and model work stops when memory is low.
Devices
- Place devices opens the Devices page in the side pane: place on walls, ceilings and roofs, linked faces too, snapping to boxes, heights and spacing.
- The Devices list names each device by its family, lists its types under it and tags where it goes, such as Wall only or Any surface.
- Place devices previews each type’s shape and supports unhosted families, including MagiCAD’s.
- My settings › Devices can hand placing to Revit’s own Place Component, so devices still place if Pembris’s placing gives you trouble.
- Add to box takes more categories and compatible families that aren’t face-based, identifying unhosted placement before you accept.
Checking
- Check routes and Check project open at once and check while you work, and list conduit Pembris didn’t draw, checked only.
- Check project checks every route and conduit run before you issue; Re-route fixes our routes, several in one undo step.
- Route watch: after you edit the model, a small notice says which routes need a look. My settings › Checks can re-route broken routes, asking first or telling after.
- Record ends accepts a device that moved or turned, and adds conduit you split off or drew by hand to the route.
- Copy in the Routes window places a route, with its devices if ticked, in any view in one undo step.
- Add run data to this project… adds six schedule columns; Run data… shows the figures, updates out-of-date runs or turns it off.
- Projects with route stamps from an older build list those routes first, and you can remove just the stamps.
Circuits
- Circuits lists each board’s circuits with their longest cable lengths along joined conduit, however far it runs, conduit ending above devices and trays included.
- Labels writes board and circuit numbers on the plan. Export saves Excel, CSV or PDF, with MagiCAD’s voltage-drop and Ik min checks.
- New circuit on a board makes a Revit circuit by name; add its devices later. Add board lists a sikringsskap under a short name you can rename, and Export all exports every board at once.
- The circuit table shows every board’s circuits in one window for a second monitor. It follows your changes, measuring only the boards they touch, and renames or adds circuits in place.
- Numbering… sets where a board’s circuit numbers start and keeps reserves free, so Revit’s panel schedule shows the same numbers.
- Change number… gives any circuit another number, swapping it with the circuit that has the number or replacing that one.
Materials
- Materials opens in a resizable window on one list of what to order, problems first, with Counts, Cables and Order as tabs.
- Export saves one plain file. Map a type with an EL number there, or in Devices.
- Symbol legend, an experiment in My settings › Experimental, lists device symbols, EL numbers and descriptions to copy, export or place on a sheet. Symbols no plan shows keep a dashed box.
Settings
- My settings opens on Routing, each row a label and its control. Project settings holds what a project sets for everyone, with a lock on each row.
- Projects saved by older versions offer a review of what they keep.
- Set each kind of element to Avoid or Go through, and add rules for your own families with Pick from model. Beams, walls and ceilings are Go through by default.
- My settings › Performance has a Search harder slider, from Faster to Better routes.
- My settings › Appearance chooses the Routes highlight and problem colours, a still or bold highlight, and each kind of zone’s colour.
- My settings › Checks turns kinds of route check off, and Routes says which are off.
- Beta builds have My settings › Experimental, where unfinished features can be tried one at a time, each off until you turn it on.
- When your administrator manages the settings, My settings shows them read-only.
Licensing
- Activate with your administrator’s code, or use their licence file, for up to three weeks of offline work.
- Where your company allows it, new versions download in the background and install when Revit closes. Every package is signed, and Pembris Electrical Setup can also go back to an older version.
- Join Beta from the licence dialog where your company allows it; leaving goes back to the newest stable version.
- The licence dialog is shorter, and Release this PC, under its More, frees the seat for another PC.
Interface
- Works in Revit 2025 and 2026, light or dark, from the Route, Devices, Check and Quantities panels and one Settings menu. Icons stay crisp at any display scaling.
- The side pane’s Home shows what needs a look first, with Routes and Devices docked beside it.
- Dialogs are short: what was found and what to do next, one Show in view, and rare actions under More.
- Buttons, rows and fields fade between states and give a little when pressed; with Windows animations off, states change at once.
- What’s new, a welcome window on the first start after an install, Help and F1, and Send feedback with the version details filled in.
- Collect diagnostics saves logs and settings in one zip for support.
- Statistics shows how much you use each tool and the time saved, with an opt-in to share a copy with Pembris.
- When a tool hits an unexpected error, it reports what failed to Pembris, and recovered errors too where your company allows it. Paths, names, IDs and model content are taken out first, and nothing is shown.