Check panel

Check project

Every route in the project checked before you issue the model.

Check every route in the project before a model is issued or sent to coordination, including conduit Pembris didn’t draw. You get a short list of what’s wrong, a one-click fix where there is one, and a list to hand on.

Overview

  • Counts by kind

    Clashes, runs over the bend limit, missing fittings, unjoined ends and anything that couldn’t be checked.

  • An honest pass

    It says every route passes only when every route and run was checked in full.

  • A list to hand on

    More › Copy list puts the routes shown on the clipboard, ready to paste into a spreadsheet.

Watch: Check project

Count every problem before issue, then fix routes with Re-route.

What it supports

Each capability and its status today. Planned items are on the roadmap, not yet built.

  • Supported
  • Partial
  • Planned
  • Not supported

What it checks

  • Every route in the project

    Whatever the view shows; up to 500 at a time, then Check next routes.

    Supported
  • Clashes, bends, missing fittings and unjoined ends

    Supported
  • Conduit Pembris didn’t draw

    Checked and counted in the same filters, but never fixed.

    Partial
  • Estimated tray landing load

    Only with the opt-in project tray capacity, and an estimate, not cable fill.

    Partial
  • Part of a project passed off as the whole

    Over 20,000 route elements or conduits, or a closed workset, refuses and checks nothing.

    Not supported
  • A certificate for the whole model

    It checks conduit routes, nothing else.

    Not supported

Fixes

  • Filter by kind of problem

    Each active filter shows as a chip that removes it.

    Supported
  • Re-route where it helps

    Not on unjoined ends, where Revit would refuse the same join again.

    Supported
  • Copy list

    One row per route, tab-separated.

    Supported
  • Fix conduit Pembris didn’t draw

    Only Show, Select and Copy list.

    Not supported

Next

  • Findings that say what may not comply

    Citing the clause of the project’s code; the installer decides.

    Planned
  • An advisory report as PDF and CSV

    Never a declaration of conformity.

    Planned
  • Fill and segregation

    Conduit and tray fill, and power kept apart from data and other services.

    Planned
  • Fire penetrations

    Every fire-rated wall or floor a route passes, listed for the firestop contractor.

    Planned
  • Revit 2025Supported

    Autodesk Revit 2025 on Windows.

  • Revit 2026Supported

    Autodesk Revit 2026 on Windows.

  • Linked modelsPartial

    Checks the host model’s routes and conduit; linked models aren’t read.

  • MagiCAD contentPartial

    MagiCAD families work like any other Revit family; there is no MagiCAD-specific handling.

  • Conduit drawn by handPartial

    Checked and counted, and a problem stops the pass, but it gets no fix.

Settings

Where to change how it behaves.

My settings › Checks
Which checks run and their tolerances. Missing fittings and unjoined ends are always checked.
My settings › Routing › Bends
The bend limit runs are counted against (360° by default).
Change drop options › Project tray capacity…
Turns on the tray landing load report for this project.

Guides for Check project

Open collection