Check routes and Check project list conduit someone drew by hand next to Pembris Electrical’s routes, so nothing is left out of a check. That conduit is only checked: no fix is ever offered for it.
How it is listed
- Each run is listed as Not drawn by Pembris, named after its smallest element ID. Its row shows By hand, which is never hidden.
- A run is followed along its joins, through conduit and two-way fittings, to a device, tee, conduit body or one of our routes. Each element is listed once.
- Check routes reads hand-drawn conduit in the selection, else the view: at most 2,000 conduits, with a note when more were left out. Check project reads every conduit in the host model.
- In the pane, Filter › Drawn by hand lists only these.
What is checked
Conduit drawn by hand
- Supported
Clash and Too close
- Supported
Not joined and Missing fitting
- Supported
Too many bends
- Supported
Stay inside and Keep out zones
- Partial
Branching runs
One Not checked card that says why
- Partial
Runs over 200 conduits and fittings
Not checked, with why
- Not supported
Conduit in linked models
Not read
- Not supported
Fixes
Show, Select, Open in 3D and Copy list only
What you can do with it
Show it, zoom to a finding, Select it, Open in 3D and Copy list. With some of our routes ticked as well, a line says "N are drawn by hand: Show and Select only", and Re-route and Remove take only ours.
In Check project
Conduit drawn by hand counts in the same filters as our routes. A clash in it, or a run that couldn’t be checked, stops the project from passing.
Conduit drawn into one of our routes
If you split a route conduit, or replace part of a route with your own conduit and elbows, that conduit isn’t listed on its own. It is read with the route, which shows Split by hand or Edited by hand as a note, and Record ends makes it part of the route. Until then Re-route is off for that route. See Record ends.