Check routes and Check project list conduit someone drew by hand next to Pembris Electrical’s routes, so nothing is left out of a check. That conduit is only checked: no fix is ever offered for it.

How it is listed

  • Each run is listed as Not drawn by Pembris, named after its smallest element ID. Its row shows By hand, which is never hidden.
  • A run is followed along its joins, through conduit and two-way fittings, to a device, tee, conduit body or one of our routes. Each element is listed once.
  • Check routes reads hand-drawn conduit in the selection, else the view: at most 2,000 conduits, with a note when more were left out. Check project reads every conduit in the host model.
  • In the pane, Filter › Drawn by hand lists only these.

What is checked

Conduit drawn by hand

  • Clash and Too close

    Supported
  • Not joined and Missing fitting

    Supported
  • Too many bends

    Supported
  • Stay inside and Keep out zones

    Supported
  • Branching runs

    One Not checked card that says why

    Partial
  • Runs over 200 conduits and fittings

    Not checked, with why

    Partial
  • Conduit in linked models

    Not read

    Not supported
  • Fixes

    Show, Select, Open in 3D and Copy list only

    Not supported

What you can do with it

Show it, zoom to a finding, Select it, Open in 3D and Copy list. With some of our routes ticked as well, a line says "N are drawn by hand: Show and Select only", and Re-route and Remove take only ours.

In Check project

Conduit drawn by hand counts in the same filters as our routes. A clash in it, or a run that couldn’t be checked, stops the project from passing.

Conduit drawn into one of our routes

If you split a route conduit, or replace part of a route with your own conduit and elbows, that conduit isn’t listed on its own. It is read with the route, which shows Split by hand or Edited by hand as a note, and Record ends makes it part of the route. Until then Re-route is off for that route. See Record ends.