Skip to main content
Route panel

Drop to tray

Every selected device gets its own drop to the nearest cable tray.

Run conduit from devices to cable trays without drawing every drop by hand. Change the device list, let it choose the tray or pick one, and keep the drops that work even when some devices can’t reach.

Overview

  • Many devices at once

    One review and one undo step for the whole batch, with no fixed limit on the number of devices.

  • Automatic or chosen tray

    It tries the nearest trays, or only the one you pick. The tray itself is never changed.

  • Keeps what works

    Add N of M drops keeps the reachable ones and leaves the devices that failed selected.

Watch: Drop to tray

Each selected device gets its own drop to the nearest cable tray.

What it supports

Each capability and its status today. Planned items are on the roadmap, not yet built.

  • Supported
  • Partial
  • Planned
  • Not supported

Devices and trays

  • Edit the device list

    Start from the selection, or add devices in the view that have no route yet.

    Supported
  • Trays in this model and in loaded links

    Angled, sloped, vertical and rotated-link trays included.

    Supported
  • Bottom, side or top entry

    Bottom and side are on by default; top is optional.

    Supported
  • Reach from 500 to 30,000 mm

    10 m by default.

    Supported
  • Change the tray or move devices

    Drops end at the tray, and tray ends stay deliberately unjoined.

    Not supported

Drop content

  • Rigid conduit

    Uses the device sizes and the project’s conduit catalogue.

    Supported
  • ABB Adaptaflex SN20, SN25 and SN32 flexible drops

    Generated fittings with real connectors, catalogue diameters and bend radii.

    Supported
  • Cablofil clamps

    Only with verified clamps per size already in the project; missing or changed content sends you to Drop options.

    Partial
  • Re-route a drop

    Keeps its tray, conduit type, size, flexible product and clamp.

    Supported

Tray landing load

  • Estimated landing load

    Opt-in per project. An estimate over nominal tray width × height, not cable fill.

    Partial
  • Cable fill or compliance

    External and through cables and downstream sections aren’t counted, so it can’t say a tray complies.

    Not supported
  • Conduit and tray fill

    From cable outside diameters against a verified limit.

    Planned
  • Revit 2025Supported

    Autodesk Revit 2025 on Windows.

  • Revit 2026Supported

    Autodesk Revit 2026 on Windows.

  • Linked modelsSupported

    Drops to trays in loaded links. The landing-load estimate leaves drops in linked models out.

  • MagiCAD contentPartial

    MagiCAD families work like any other Revit family; there is no MagiCAD-specific handling.

  • Conduit drawn by handSupported

    Existing conduit is kept clear of; runs and fittings in the selection are left out of the list.

Settings

Where to change how it behaves.

My settings › Routing
How far Drop to tray looks for a tray (10 m by default) and which tray faces a drop may enter.
My settings › This PC › Performance
How many trays one drop tries (4 by default, up to 16) and the extra memory it may use.
Drop to tray › More › Change drop options
Rigid or flexible content, reach and clamps, remembered for this document until Revit closes.
Change drop options › Project tray capacity…
Landing load target (40 %) and reserve (20 % of it), saved in the project. Off unless you turn it on.