A route starts and ends at a device or at the open end of an existing run. Pembris Electrical works out which opening to use at each end; you can still choose one yourself in the review.
Start and end points
- Supported
Devices with conduit connectors
Every free opening is a candidate. The route uses one and joins it.
- Supported
Sockets, switches and lights without a conduit connector
The conduit ends at the device, and the review marks that end Not joined.
- Supported
The open end of a conduit or fitting
Drawn by Pembris Electrical or by hand. The new conduit joins it.
- Supported
A device inside another element
Such as a socket in its junction box. It gets a short straight way out.
- Partial
Sloped or turned runs
You can pick them, but an end more than 0.5° off level, plumb or the plan axes is refused before any suggestion, with nothing changed.
- Not supported
A device with every opening taken
Each opening is used once. The status bar says why.
Select first or pick
Select the two ends before you click Route A→B and the picks are skipped. With three or more usable devices selected, it offers Connect devices instead. Otherwise it asks for a start, then an end; Esc cancels a pick.
Which opening a route uses
Every free conduit connector on a device is a candidate, and the search chooses the pair. The routing direction only makes some openings cheaper, so a box whose preferred openings are taken still gets a route.
| Routing direction | Effect |
|---|---|
| Automatic | No opening is preferred. |
| Prefer upward | Top openings are preferred. The default. |
| Prefer sideways | Side openings are preferred. |
| Prefer downward | Bottom openings are preferred. |
Set it in My settings › Routing, or for one route in More › Change layout. To use a particular opening, choose it in More › Change openings. See Change openings, layout and conduit.
Devices without a conduit connector
Most sockets, switches and lights have no conduit connector. The route then ends at the device’s insertion point, or up to 150 mm beside it for a straight run, and the review marks that end Not joined and shows any offset. Add conduit stays the default. To stop routing to these devices, turn off Conduit can end at devices without a conduit connector in My settings › Devices.
Continuing an existing run
- The new conduit joins the open end you picked.
- It keeps the run’s conduit type and size, and copies its Service Type. The review’s notes say so.
- The run you continue is only read. It isn’t moved, changed or made part of the new route.
A device inside another element
When every opening of a device sits inside an element set to Avoid, such as a socket inside its junction box, the route gets one short straight way out of each opening, and the review lists the crossing as a permitted penetration. If there is still no route, the message names the device and the element, and suggests moving the device or setting that kind of element to Go through.