Open circuit table (the table icon in the Circuits header) opens every board’s circuits in one window. It doesn’t block Revit, and you can resize it, maximise it or drag it to a second monitor. It reopens where you left it until Revit closes.

The circuit table: each board’s heading, then its circuits in place order with their longest lengths.

What it shows

The title counts the circuits and boards. Boards are listed by name, each heading with its floor, circuit count and longest length, Numbering… and New circuit. Under it, in place order, come a Kept free row and reserves as in the pane, and each circuit’s number, name, devices, longest length (with ~, ? and – as in the pane), end device and what needs a look. A circuit made with Revit’s tools shows a lock: rename it in its Properties.

Find and filter

  • Find filters by circuit, board or end device.
  • Floor shows one floor’s boards.
  • Needs a look, with its count, shows only circuits with a problem.
  • Export… exports the boards shown, first measuring any that aren’t current, within the pane’s limits of 500 boards and 3 minutes. Copy list copies them.

Edit in place

Picking a row shows its devices in the view. Circuits New circuit made can be renamed in place; any circuit can get another number, just as with Change number….

F2
Rename the picked circuit, if New circuit made it (or double-click its name)
Enter
Save the name or number
Esc
Leave the cell without saving
0–9
Type a new number on the picked circuit (or double-click the No. cell)
  • A free number is saved at once with Enter. A taken number asks, as Change number does, offering Swap or Replace.
  • Tick two circuits on one board to get Swap.
  • New circuit under a board adds a line to type the name in; Enter makes it and picks it out. The circuit setup is asked first, as in the pane.

It follows your changes

The table measures each board once, one board at a time, while Revit stays usable (“Measuring lengths: 2 of 6 boards done…”). A second after any change to the project, yours, an Undo or a sync, it reads the circuits again. Names, numbers and device counts change at once, and only the boards the change touched are measured again, their lengths showing Measuring… until then.

You seeWhat to do
May be out of date, lengths mutedA change touched more than five boards or over 2,000 elements. Click Measure again in the banner.
A board that couldn’t be measuredIts heading and the banner say why. Click Measure again.
The circuits couldn’t be readWorking out what a change touched and reading the circuits again took over 30 seconds, so every board is marked May be out of date. Click Measure again.

With another project active

The table says so, keeps its own project’s circuits on screen, dimmed, and acts on none of them until that project is active again. It closes with its project. A project with no boards says No circuits yet, with Add board.